Title: (Paraphrase problem in a
single statement)IDCAMS modifies user
supplied parameters without notification
Detailed
Problem Description: (Description of what you want changed - 400 character entry limit)
It has occurred that an
IDCAMS DEFINE CLUSTER user supplied parameter has been overridden which has
resulted in the SPACE allocation being changed from CYL to TRK and a control
area to be less than a full cylinder.
IDCAMS will still issue a return code of zero and no messages saying the
parameter has been overridden.
Priority: (Select one: Urgent
- High - Medium - Low)
Medium
Requested
Completion Date: (When? Examples: 3 months, 1 year,
Next Release) 1 year
Requirement
Type: (Select one:
Acceptability - Compatibility/Migration - Ease of Use - Feature/Function - Performance - Reliability/Availability/Serviceability
- Packaging - Interoperability)
Reliability
Business
Justification: (Why? Non-technical
business case description. Do not reword Detailed Problem
Description from above. What are the benefits to be gained by your
company, and the vendor and others?
Quantify: run time, dollars, manpower, etc. Why should the vendor do this for the customer?)
It would save time investigating why a LISTCAT
of a CLUSTER does not match the supplied definition and to prevent a possible
performance problem being promoted into production.
Solution: (Optional)(Desired/undesired elements Note: Making a suggestion may limit a
vendors ability to deliver a solution)
Have IDCAMS print a message when a user
supplied parameter is overridden and why. Also, set a RC other than 0 (maybe
1).
Impact: (Optional) (How
will your company’s business be affected if a solution is not delivered?)
Company Name: Systems & Communications Sciences, Inc. contracted to the State of
New Hampshire
Author Name: Gary
Shiminsky Author Title: Senior systems programmer
Author
Address: 27 Hazen Dr, Concord, NH 03301
Author E-mail: Gary.Shiminsky@sacsi.com
Telephone: