WAVV Requirement Form

 

Date: 4/23/2003                                           Requirement #:  WAVV200325

Product Name:    VSE/AF        Product Release# (or state “current”): 2.6

Vendor Name:     IBM

 

Title: (Paraphrase problem in a single statement)Stop segemtation of ABEND output when using 3800 printer support.

Detailed Problem Description: (Description of what you want changed - 400 character entry limit)

 

IBM provides us with a local fix to stop segmentation of the JCL and abend output when using 3800 printer support.  This segmentation does not occur when spooling to PRT1 printers.

                                                                                            

Priority: (Select one: Urgent - High - Medium - Low) Medium

Requested Completion Date: (When? Examples: 3 months, 1 year, Next Release) Release 2.7

Requirement Type: (Select one: Acceptability - Compatibility/Migration - Ease of Use - Feature/Function - Performance - Reliability/Availability/Serviceability - Packaging - Interoperability)

Compatibility/Migration

Business Justification: (Why? Non-technical business case description. Do not reword Detailed Problem Description from above. What are the benefits to be gained by your company, and the vendor and others?  Quantify: run time, dollars, manpower, etc.   Why should the vendor do this for the customer?)

 

With this fix print is created in the same way (same number of segements) when using either PRT1 or 3800 spooled printers.

Solution: (Optional)(Desired/undesired elements Note: Making a suggestion may limit a vendors ability to deliver a solution)

 

Make this a permanent change to VSE.

CORRECT 5686-066-06-65C : DY99996  /* VSE/ESA 2.6.1 */

REQ PRE=UD51943                                                

REQ PRE=UD52144                                                

REQ PRE=UD52176                                                

AFFECTS PHASE=$IJBSDMP                                          

ALTER 533A 4110B1F8:45F09070      /* CHECK POWER FLAG         */

ALTER 5614 91020241:5890B0EC      /* GET BASE OF PATCH AREA   */

ALTER 5618 47E0A4FA:45F09070      /* CHECK POWER FLAG         */

ALTER 1C08 40C19393:BF1F047C      /* POWCAT PRESENT?          */

ALTER 1C0C 40D9:078F              /* NO                       */

ALTER 1C0E 898788A3:91101277      /* CAF6PDMP SET?            */

ALTER 1C12 A240:078F              /* NO                       */

ALTER 1C14 D985A285:9510F001      /* FROM 1. SETPRT?          */

ALTER 1C18 99A58584:4780A24E      /* YES, SKIP SETPRT         */

ALTER 1C1C 4B40E4E2:47F0A546      /* SKIP SETPRT              */

RESOLVES 'NO SETPRT IF POWER FLAG IS SET'                      

Impact: (Optional) (How will your company’s business be affected if a solution is not delivered?)

 

The fix will have to be maintained between service and release levels.

 

Company Name:        BISYS Banking Solutions                                                                 

Author Name:            Steve Mondy                            Author Title: Technical Support Manager

Author Address:         11 Greenway Plaza, Suite 300, Houston, TX 77046

Author E-mail:            steve.mondy@bisys.com

Telephone:                 (713) 965-8457